Part G Water Calculations: 125 or 110 Litres?

Your planning permission sets the water target, not the Building Regulations. How to tell which figure applies, and how to meet it.
Rainfall shower head in a grey tiled shower enclosure

Part G Water Calculations: 125 or 110 Litres?

Every new home in England needs a Part G water calculation before building control signs it off. The question we get most is which figure to design to: 125 or 110 litres per person per day. The answer is in your planning permission, not in the Building Regulations.

The two figures

Regulation 36 of the Building Regulations 2010 limits how much water a new dwelling is designed to use. The standard is 125 litres per person per day. The optional requirement is 110 litres per person per day.

Both figures include a fixed 5 litres per person per day for outdoor use. It is already in the target, not added on top.

Part G water efficiency covers new-build homes and homes formed by a change of use, such as offices or a large house turned into flats. It does not apply to extensions.

What makes 110 litres apply

Only a planning condition. The optional requirement applies where the planning permission specifies it and makes it a condition that it must be met. If there is no such condition, the target is 125 litres, even if the design team wanted to go lower.

Check the decision notice first. Look for a condition that mentions water efficiency, 110 litres or the optional requirement of Part G. Some conditions also ask for evidence to go to the planning authority. That is a separate step from building control, so read the wording.

Where the optional requirement applies, you must tell building control. At the end of the job the notice to building control states which figure applies and the calculated water use for each home. For most buildings it goes in no later than five days after the work is complete. For higher-risk buildings it goes with the completion certificate application.

And 105 litres in London?

London Plan Policy SI 5 asks boroughs to use planning conditions to keep mains water use to 105 litres or less per head per day, excluding up to 5 litres for outdoor use. The policy ties this to the optional requirement of the Building Regulations and says it should apply across London.

So 105 is the same target as 110, with the outdoor allowance taken out. A London scheme with a water condition is designed to 110 for building control, and the internal figure is what the planning paperwork quotes.

Two ways to show compliance

The fittings approach. Approved Document G sets maximum figures for each fitting. If every fitting in the home is at or below them, it meets the target without a full calculation. For the 110 litre optional requirement (Table 2.2) the limits are:

  • WC: 4/2.6 litres dual flush
  • Shower: 8 litres a minute
  • Bath: 170 litres
  • Basin taps: 5 litres a minute
  • Sink taps: 6 litres a minute
  • Dishwasher: 1.25 litres per place setting
  • Washing machine: 8.17 litres per kilogram

For the 125 litre standard (Table 2.1) the limits are looser: a 6/4 litre dual flush or 4.5 litre single flush WC, a 10 litre shower, a 185 litre bath, 6 litre basin taps and 8 litre sink taps.

The fittings approach can't be used for a home with no shower. A bath-only flat needs the full calculation.

The water efficiency calculation. This is the government method in Appendix A of Approved Document G. It takes the flow rate or volume of each fitting and works out the total for the home. It gives you room to trade: a more generous shower can be balanced by lower-flow taps or a smaller bath. On most schemes it is the easier route, because the fittings approach leaves no slack on any single item.

Where specifications go wrong

In our experience, these push a home over the limit:

  • Showers. Rainfall heads and body jets often run well above 8 litres a minute. Check the flow rate at the head, not just the valve.
  • Large baths. A big bath in a flat with a 110 litre condition uses up much of the allowance.
  • Kitchen taps. Designer taps often have high flow rates. A flow regulator usually fixes it.
  • Swaps on site. The calculation is only as good as the fittings actually fitted. If the contractor changes the sanitaryware, the calculation needs rerunning before the notice goes in.

The cheapest fix is timing. Get the calculation done before the sanitaryware is ordered, not after it is on site.

Changes coming

Defra consulted from 23 September to 16 December 2025 on tighter limits: 125 down to 105 litres for all new homes, and the optional requirement down from 110 to 100. At 28 November 2026 the government response has not been published and the law has not changed. Until it does, the 125 and 110 figures apply. We post rule changes on our industry updates page.

Questions we get asked

Does Part G apply to a conversion? Yes, where the work creates a new dwelling, for example an office turned into flats. It does not apply to an extension.

Our condition says 110, but the government has proposed 100. Which do we use? The figure in your planning condition and the current regulations. The consultation is not law yet.

Do we need a calculation if all our fittings meet Table 2.2? Not a full one, as long as the home has a shower. Building control still needs the notice stating the target is met using the fittings approach.

How much does a Part G water calculation cost? From £65+VAT, depending on the size of the scheme. Turnaround is 5 working days once we have the fittings schedule. If we are doing your SAP calculations, send the schedule with the drawings and we'll run both together.

More: Part G water efficiency calculations, SAP calculations and EPCs, energy assessments for new dwellings, sustainability statements, and our guides to design-stage and as-built SAP and the London Plan energy hierarchy.

Email your drawings or WhatsApp us for a quote.

Walk-in shower with a black shower head and white tiled walls

Send Us Your Drawings

Send us your fittings schedule and the planning decision notice, and we will tell you which target applies and whether your fittings meet it, with a free quote.